GetConfigurationResponse from 7CS1-6-2247-00026
Key Value Read only?
ChargePointVendor LITEON true
ChargePointModel EX-1762-7CS1 true
ChargePointSerialNumber 7CS1-6-2247-00026 true
HardwareVersion X7.02-V1.01 true
FirmwareVersion V1.00.94 (BBOX: V1.33) true
ProductionDate 22-47 true
EvrangeBasicAuthId true
EvrangeBasicAuthPwd true
ConnectorType SAE J1772 true
MaxAmperageConnector 32.0 true
MeterType Built-in meter true
ReaderType Built-in RFID true
DSMRType Not Support true
Connectivity Cellular false
BasicAuthId false
BasicAuthPwd false
FTPUserName false
FTPPassword false
MNC 311 true
ICCID 89148000008299142723"311480775570342 true
IMSI 311480775570342 true
IMEI 350528320373505 true
MEID 350528320373505 true
CellularDialNumber *99# false
CellularApnName wyleslte.gw7.vzwentp false
CellularApnPdpType 1 false
CellularApnUser false
CellularApnPassword false
CellularPinCode false
MobileSignalStrength -51 true
Latitude 0.000000 true
Longitude 0.000000 true
LastBootTimestamp 1783473741394 true
SSID false
BSSID false
WiFiPassword false
WiFiSecurity AUTO false
HideWiFiAPSSID 0 true
WiFiSignalStrength true
WiFiStationOnly on false
LEDBrightness 1 false
ChargePointId 7CS1-6-2247-00026 false
ProtocolName ocpp1.6J true
CentralSystemURL ws://ocppwss.dev.dirtroadev.com/steve/websocket/CentralSystemService false
MessageTransportLayer WS false
BootNotificationInterval 900 false
BootNotificationRetries -1 false
PDUTimeout 30 false
DownloadFirmwareInterval 300 false
DownloadFirmwareRetries 3 false
UploadDiagnosticsInterval 300 false
UploadDiagnosticsRetries 3 false
UnitPrice 0.75 false
ParkingFee 0.00 false
ParkingFeeCharging 0.00 false
DefaultPrice NULL false
SetUserPrice NULL false
RunningCost 0.000 false
FinalCost 0.000 false
ActivationFee 0.00 false
CustomDisplayCostAndPrice false false
NotificationAfterSoftReset 0 false
OutputPowerType AC true
PowerPhaseConnected 1 true
MaxAmperageHWSetting 32.0 true
MaxAmperageFWSetting 32.0 false
PWMAmperage 0.00 true
RealAmperage 0.00 true
ColdLoadPickupMaxDelay 720 false
OfflinePlugAndChargeToggle false false
PlugAndChargeId false
ReservationSupported true false
ResumeCharging false false
rfidAvailability true false
VentilationArea false false
SkipHeartBeat false false
RestartTime 0 false
RestartCounter 3 false
TemperatureLow -30 false
TemperatureHigh 88 false
VoltageLow 170 false
VoltageHigh 270 false
OperationMode Gateway false
GatewaySerialNumber false
UseExternalGateway false false
LlmEnable true false
LlmGroupId false
LlmNumberOfChargers 1 false
LlmGridMaxAmperage 32 false
LlmChargingPolicy FIFS false
FallbackAmperage 6.00 false
AllowOfflineTxForUnknownId false false
AuthorizationCacheEnabled false false
AuthorizeRemoteTxRequests true false
BlinkRepeat 30 true
ClockAlignedDataInterval 0 false
ConnectionTimeOut 60 false
GetConfigurationMaxKeys 128 true
HeartbeatInterval 60 false
LightIntensity 100 true
LocalAuthorizeOffline true false
LocalPreAuthorize true false
MaxEnergyOnInvalidId 7680 false
MeterValuesAlignedData Current.Import,Current.Offered,Energy.Active.Import.Register,Energy.Active.Import.Interval,Power.Active.Import,Power.Offered,Temperature,Voltage false
MeterValuesAlignedDataMaxLength 8 true
MeterValuesSampledData Current.Import,Current.Offered,Energy.Active.Import.Register,Power.Active.Import,Power.Offered,Temperature,Voltage false
MeterValuesSampledDataMaxLength 7 true
MeterValueSampleInterval 60 false
MinimumStatusDuration 0 false
NumberOfConnectors 1 true
ResetRetries 0 false
ConnectorPhaseRotation 0 false
ConnectorPhaseRotationMaxLength 1 true
StopTransactionOnEVSideDisconnect true false
StopTransactionOnInvalidId true false
StopTxnAlignedData Current.Import,Current.Offered,Energy.Active.Import.Register,Energy.Active.Import.Interval,Power.Offered,Temperature,Voltage false
StopTxnAlignedDataMaxLength 7 true
StopTxnSampledData Current.Import,Current.Offered,Energy.Active.Import.Register,Power.Offered,Temperature,Voltage false
StopTxnSampledDataMaxLength 6 true
SupportedFeatureProfiles Core,Firmware Management,Local Auth List Management,Reservation,Smart Charging,Remote Trigger true
SupportedFeatureProfilesMaxLength 6 true
TransactionMessageAttempts 10 false
TransactionMessageRetryInterval 10 false
UnlockConnectorOnEVSideDisconnect false false
WebSocketPingInterval 180 false
LocalAuthListEnabled true false
LocalAuthListMaxLength 1000 true
SendLocalListMaxLength 1000 true